Revision 8
Cell Signaling Technology

Orders: 877-616-CELL (2355) [email protected]

Support: 877-678-TECH (8324)

Web: [email protected] cellsignal.com

3 Trask LaneDanversMassachusetts01923USA
For Research Use Only. Not for Use in Diagnostic Procedures.
Applications:

C&T

:

:

:

:

Product Information

Storage

Store all components at -20ºC. This product is stable for 18 months if stored properly.

Specificity / Sensitivity

This kit can generate DNA libraries using CUT&Tag DNA. Note: While CUT&Tag DNA libraries generated for histone modifications typically show robust signal in Agilent Bioanalyzer or TapeStation systems analysis, libraries generated for non-histone proteins such as transcription factors and cofactors often have very weak or even no visible signal using Bioanalyzer or TapeStation systems, but still generate NG-sequencing results with high mapping rates, high numbers of identified binding peaks, and decent signal-to-noise ratios across the whole genome.

Species Reactivity:

All Species Expected

Product Description

Next generation sequencing (NG-seq) is a high throughput method that can be used downstream of the Cleavage Under Targets and Tagmentation (CUT&Tag) assay to identify and quantify target DNA enrichment across the entire genome. The CUT&Tag Dual Index Primers and PCR Master Mix for Illumina Systems kit is ideally suited for multiplex sample preparation for NG-seq on the Illumina systems platform. This kit can be used to generate up to 96 distinct, barcoded CUT&Tag DNA libraries that can be combined into a single sequencing reaction. This product provides enough reagents to support up to 96 DNA sequencing libraries. This product is compatible with CUT&Tag DNA samples generated by CUT&Tag Assay Kit #77552 or CUT&Tag pAG-Tn5 (Loaded) #79561 and DNA samples from other tagmentation assays, such as ATAC-seq. This product is not compatible with SimpleChIP® Chromatin IP Kits (#9003, #9005, #56383) or the CUT&RUN Assay Kit #86652.

Background

Similar to Cleavage Under Targets and Release Using Nuclease (CUT&RUN), Cleavage Under Targets and Tagmentation (CUT&Tag) is a powerful technique used for probing protein-DNA interactions within the natural chromatin context of the cell (1-3). CUT&Tag has many of the same advantages as the CUT&RUN assay in that it provides a rapid, robust, and true low cell number protocol for detection of protein-DNA interactions in the cell. In addition, the CUT&Tag assay adds an in situ adaptor DNA ligation step carried out by the pAG-Tn5 enzyme, in which an adaptor DNA is ligated directly to antibody-targeted chromatin DNA fragments in the cell. As a result, subsequent DNA library preparation is much faster and easier than library preparation following the CUT&RUN assay, free from DNA end repair, A-tailing, and adaptor ligation in vitro. CUT&Tag works very well for analyzing histone modifications, in addition to mapping some transcription factor and cofactor binding.

  1. Kaya-Okur, H.S. et al. (2019) Nat Commun 10, 1930.
  2. Kaya-Okur, H.S. et al. (2020) Nat Protoc 15, 3264-3283.
  3. Henikoff, S. et al. (2021) Bio Protoc 11, e4043.

Species Reactivity

Species reactivity is determined by testing in at least one approved application (e.g., western blot).

Applications Key

C&T: CUT&Tag

Cross-Reactivity Key

H: human M: mouse R: rat Hm: hamster Mk: monkey Vir: virus Mi: mink C: chicken Dm: D. melanogaster X: Xenopus Z: zebrafish B: bovine Dg: dog Pg: pig Sc: S. cerevisiae Ce: C. elegans Hr: horse GP: Guinea Pig Rab: rabbit All: all species expected

Trademarks and Patents

Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
SimpleChIP is a registered trademark of Cell Signaling Technology, Inc.
XP is a registered trademark of Cell Signaling Technology, Inc.
U.S. Patent No. 7,429,487, foreign equivalents, and child patents deriving therefrom.
All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

使用に関する制限

法的な権限を与えられたCSTの担当者が署名した書面によって別途明示的に合意された場合を除き、 CST、その関連会社または代理店が提供する製品には以下の条件が適用されます。お客様が定める条件でここに定められた条件に含まれるものを超えるもの、 または、ここに定められた条件と異なるものは、法的な権限を与えられたCSTの担当者が別途書面にて受諾した場合を除き、拒絶され、 いかなる効力も効果も有しません。

研究専用 (For Research Use Only) またはこれに類似する表示がされた製品は、 いかなる目的についても FDA または外国もしくは国内のその他の規制機関により承認、認可または許可を受けていません。 お客様は製品を診断もしくは治療目的で使用してはならず、また、製品に表示された内容に違反する方法で使用してはなりません。 CST が販売または使用許諾する製品は、エンドユーザーであるお客様に対し、使途を研究および開発のみに限定して提供されるものです。 診断、予防もしくは治療目的で製品を使用することまたは製品を再販売 (単独であるか他の製品等の一部であるかを問いません) もしくはその他の商業的利用の目的で購入することについては、CST から別途許諾を得る必要があります。 お客様は以下の事項を遵守しなければなりません。(a) CST の製品 (単独であるか他の資材と一緒であるかを問いません) を販売、使用許諾、貸与、寄付もしくはその他の態様で第三者に譲渡したり使用させたりしてはなりません。また、商用の製品を製造するために CST の製品を使用してはなりません。(b) 複製、改変、リバースエンジニアリング、逆コンパイル、 分解または他の方法により製品の構造または技術を解明しようとしてはなりません。また、 CST の製品またはサービスと競合する製品またはサービスを開発する目的で CST の製品を使用してはなりません。(c) CST の製品の商標、商号、ロゴ、特許または著作権に関する通知または表示を除去したり改変したりしてはなりません。(d) CST の製品をCST 製品販売条件(CST’s Product Terms of Sale) および該当する書面のみに従って使用しなければなりません。(e) CST の製品に関連してお客様が使用する第三者の製品またはサービスに関する使用許諾条件、 サービス提供条件またはこれに類する合意事項を遵守しなければなりません。