Revision 3
Cell Signaling Technology

Orders: 877-616-CELL (2355) [email protected]

Support: 877-678-TECH (8324)

Web: [email protected] cellsignal.com

3 Trask LaneDanversMassachusetts01923USA
For Research Use Only. Not for Use in Diagnostic Procedures.
:

:

:

:

Product Information

Storage

All components in this kit are stable for at least 12 months when stored at the recommended temperature.

Product Description

The PTMScan® HS Immunoenrichment Companion Reagents Kit includes ten S-Trap columns and all the necessary reagents to prepare purified peptides ready for posttranslational modification enrichment. Cells or tissues from any species are supported. The kit includes supplies to prepare ten trypsin digestions of 1 mg each, which is sufficient for ten immunoenrichments with a PTMScan® HS Antibody Kit. The soluble protein content of cells and tissues vary, but 1 x 107 cells or 15-30 mg of wet tissue from mammalian sources should be sufficient. Clean peptides are ready for PTM enrichment with only one day of hands-on work and one day of hands-off drying time.

Background

Proteomics analyses of posttranslationally modified peptides rely on both high-quality enrichments and pre-enrichment sample preparation. Suspension Traps (S-Trap columns) are a convenient tool to combine protein digestion and peptide cleanup into a single procedure. The S-Trap column is a spin filter made out of quartz that can trap large particles, such as precipitated proteins, but has little to no affinity for smaller particles, such as peptides (1). Cells and tissues can be prepared in any lysis buffer of choice, but buffers containing SDS are reported to extract more protein per cell than other buffers and help to maximize the performance of S-Trap columns (2). Acidifying the cell lysate and mixing it with methanol causes the proteins to precipitate, so that they can be captured on the S-Trap column with a brief centrifugation step. Detergents, along with lipids and any other contaminants, are washed away with additional methanol. The captured proteins can then be digested with trypsin or any other appropriate enzyme. Digesting on a solid substrate such as the S-Trap column enhances the enzymatic efficiency, reducing missed cleavages in comparison to in-solution methods (3). The peptides elute easily into mass spectrometry-friendly solutions. Once dried, these purified peptides are ready to be enriched for any PTM of interest using techniques such as IMAC #20432 or PTMScan®. If desired, the peptides are also ready for direct mass spectrometry analysis without further cleanup.

The S-Trap column workflow is much faster and less laborious than in-solution digestion because it avoids a separate peptide purification procedure. Once protein extracts are collected, reduction and alkylation takes 45 minutes, loading and washing the S-Trap columns takes 15 minutes, and then the samples are allowed to digest overnight. Clean peptides are collected the next morning in less than 15 minutes. Drying in a vacuum concentrator (or lyophilizer) can be completed over the next night, so that enrichment can be completed on the third day of sample preparation.

  1. Zougman, A. et al. (2014) Proteomics 14, 1006-0.
  2. Elinger, D. et al. (2019) J Proteome Res 18, 1441-5.
  3. Ludwig, K.R. et al. (2018) J Proteome Res 17, 2480-90.

Species Reactivity

Species reactivity is determined by testing in at least one approved application (e.g., western blot).

Cross-Reactivity Key

H: human M: mouse R: rat Hm: hamster Mk: monkey Vir: virus Mi: mink C: chicken Dm: D. melanogaster X: Xenopus Z: zebrafish B: bovine Dg: dog Pg: pig Sc: S. cerevisiae Ce: C. elegans Hr: horse GP: Guinea Pig Rab: rabbit All: all species expected

Trademarks and Patents

Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
PTMScan is a registered trademark of Cell Signaling Technology, Inc.
All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

使用に関する制限

法的な権限を与えられたCSTの担当者が署名した書面によって別途明示的に合意された場合を除き、 CST、その関連会社または代理店が提供する製品には以下の条件が適用されます。お客様が定める条件でここに定められた条件に含まれるものを超えるもの、 または、ここに定められた条件と異なるものは、法的な権限を与えられたCSTの担当者が別途書面にて受諾した場合を除き、拒絶され、 いかなる効力も効果も有しません。

研究専用 (For Research Use Only) またはこれに類似する表示がされた製品は、 いかなる目的についても FDA または外国もしくは国内のその他の規制機関により承認、認可または許可を受けていません。 お客様は製品を診断もしくは治療目的で使用してはならず、また、製品に表示された内容に違反する方法で使用してはなりません。 CST が販売または使用許諾する製品は、エンドユーザーであるお客様に対し、使途を研究および開発のみに限定して提供されるものです。 診断、予防もしくは治療目的で製品を使用することまたは製品を再販売 (単独であるか他の製品等の一部であるかを問いません) もしくはその他の商業的利用の目的で購入することについては、CST から別途許諾を得る必要があります。 お客様は以下の事項を遵守しなければなりません。(a) CST の製品 (単独であるか他の資材と一緒であるかを問いません) を販売、使用許諾、貸与、寄付もしくはその他の態様で第三者に譲渡したり使用させたりしてはなりません。また、商用の製品を製造するために CST の製品を使用してはなりません。(b) 複製、改変、リバースエンジニアリング、逆コンパイル、 分解または他の方法により製品の構造または技術を解明しようとしてはなりません。また、 CST の製品またはサービスと競合する製品またはサービスを開発する目的で CST の製品を使用してはなりません。(c) CST の製品の商標、商号、ロゴ、特許または著作権に関する通知または表示を除去したり改変したりしてはなりません。(d) CST の製品をCST 製品販売条件(CST’s Product Terms of Sale) および該当する書面のみに従って使用しなければなりません。(e) CST の製品に関連してお客様が使用する第三者の製品またはサービスに関する使用許諾条件、 サービス提供条件またはこれに類する合意事項を遵守しなければなりません。