Revision 9
Cell Signaling Technology

Orders: 877-616-CELL (2355) [email protected]

Support: 877-678-TECH (8324)

Web: [email protected] cellsignal.com

3 Trask LaneDanversMassachusetts01923USA
For Research Use Only. Not for Use in Diagnostic Procedures.
Applications:

FC-FP, FC-L

REACTIVITY:

Rab

SENSITIVITY:

MW (kDa):

Source/Isotype:

Rabbit 

Product Information

Product Usage Information

The optimal dilution of the anti-biotin antibody should be determined by titration. However, a final dilution of 1:500 – 1:2000 should yield acceptable results for flow cytometry assays.

Storage

Supplied in PBS (pH 7.2), less than 0.1% sodium azide and 2 mg/ml BSA. Store at 4°C. Do not aliquot the antibody. Protect from light. Do not freeze.

Specificity / Sensitivity

Anti-Biotin (D5A7) Rabbit mAb (Alexa Fluor® 647 Conjugate) recognizes biotin attached to proteins, peptides, oligonucleotides, and solid matrices.

Species Reactivity:

Rabbit

Source / Purification

Monoclonal antibody is produced by immunizing animals with biotinylated KLH.

Product Description

This Cell Signaling Technology antibody is conjugated to Alexa Fluor® 647 fluorescent dye and tested in-house for detection of biotinylated antibodies for direct flow cytometric analysis.

Background

Biotin is a water-soluble B complex vitamin (vitamin H or B7) that serves as a coenzyme in various metabolic functions. It transfers carbon dioxide for five carboxylase enzymes and is involved in the TCA cycle and gluconeogenesis. In addition, all cells require biotin for cell proliferation, production of fatty acids, and metabolism of fats and amino acids (1). Biotin recycling and attachment to histone proteins is catalyzed by an enzyme named biotinidase. Histone biotinylation is involved in regulating telomere attrition and cellular senescence. Biotinidase deficiency is a rare genetic disorder that can cause neurological and cutaneous symptoms if left untreated (2). Biotin has a high affinity for its natural ligand, avidin. The complex and irregular structure of the biotin-binding site makes it highly optimized for biotin binding and confers great specificity to the avidin-biotin complexes (3). This remarkable affinity has been exploited for numerous immunoassays, including ELISA, Flow Cytometry, Immunofluorescence, In Situ Hybridization, Affinity Chromatography, and Immunohistochemistry. Anti-biotin (D5A7) Rabbit mAb #5597 can be used as an alternative to avidins in order to minimize background and maximize signal intensity.

  1. Zempleni, J. et al. (2010) Biofactors 35, 36-46.
  2. Pindolia, K. et al. (2011) Mol Genet Metab 102, 161-9.
  3. Reznik, G.O. et al. (1998) Proc Natl Acad Sci U S A 95, 13525-30.

Species Reactivity

Species reactivity is determined by testing in at least one approved application (e.g., western blot).

Applications Key

FC-FP: Flow Cytometry (Fixed/Permeabilized) FC-L: Flow Cytometry (Live)

Cross-Reactivity Key

H: human M: mouse R: rat Hm: hamster Mk: monkey Vir: virus Mi: mink C: chicken Dm: D. melanogaster X: Xenopus Z: zebrafish B: bovine Dg: dog Pg: pig Sc: S. cerevisiae Ce: C. elegans Hr: horse GP: Guinea Pig Rab: rabbit All: all species expected

Trademarks and Patents

Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
This product is provided under an intellectual property license from Life Technologies Corporation. The transfer of this product is conditioned on the buyer using the purchased product solely in research conducted by the buyer, excluding contract research or any fee for service research, and the buyer must not (1) use this product or its components for (a) diagnostic, therapeutic or prophylactic purposes; (b) testing, analysis or screening services, or information in return for compensation on a per-test basis; or (c) manufacturing or quality assurance or quality control, and/or (2) sell or transfer this product or its components for resale, whether or not resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or [email protected].
All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

使用に関する制限

法的な権限を与えられたCSTの担当者が署名した書面によって別途明示的に合意された場合を除き、 CST、その関連会社または代理店が提供する製品には以下の条件が適用されます。お客様が定める条件でここに定められた条件に含まれるものを超えるもの、 または、ここに定められた条件と異なるものは、法的な権限を与えられたCSTの担当者が別途書面にて受諾した場合を除き、拒絶され、 いかなる効力も効果も有しません。

研究専用 (For Research Use Only) またはこれに類似する表示がされた製品は、 いかなる目的についても FDA または外国もしくは国内のその他の規制機関により承認、認可または許可を受けていません。 お客様は製品を診断もしくは治療目的で使用してはならず、また、製品に表示された内容に違反する方法で使用してはなりません。 CST が販売または使用許諾する製品は、エンドユーザーであるお客様に対し、使途を研究および開発のみに限定して提供されるものです。 診断、予防もしくは治療目的で製品を使用することまたは製品を再販売 (単独であるか他の製品等の一部であるかを問いません) もしくはその他の商業的利用の目的で購入することについては、CST から別途許諾を得る必要があります。 お客様は以下の事項を遵守しなければなりません。(a) CST の製品 (単独であるか他の資材と一緒であるかを問いません) を販売、使用許諾、貸与、寄付もしくはその他の態様で第三者に譲渡したり使用させたりしてはなりません。また、商用の製品を製造するために CST の製品を使用してはなりません。(b) 複製、改変、リバースエンジニアリング、逆コンパイル、 分解または他の方法により製品の構造または技術を解明しようとしてはなりません。また、 CST の製品またはサービスと競合する製品またはサービスを開発する目的で CST の製品を使用してはなりません。(c) CST の製品の商標、商号、ロゴ、特許または著作権に関する通知または表示を除去したり改変したりしてはなりません。(d) CST の製品をCST 製品販売条件(CST’s Product Terms of Sale) および該当する書面のみに従って使用しなければなりません。(e) CST の製品に関連してお客様が使用する第三者の製品またはサービスに関する使用許諾条件、 サービス提供条件またはこれに類する合意事項を遵守しなければなりません。