Revision 2

#6883Store at RT

Cell Signaling Technology

Orders: 877-616-CELL (2355) [email protected]

Support: 877-678-TECH (8324)

Web: [email protected] cellsignal.com

3 Trask LaneDanversMassachusetts01923USA
For Research Use Only. Not for Use in Diagnostic Procedures.
Kit Includes Petite Kit (P) Quantity Small Kit (S) Quantity
SignalFire™ ECL Reagent A 1 x 25 ml 1 x 250 ml
SignalFire™ ECL Reagent B 1 x 25 ml 1 x 250 ml
Applications:

WB

:

:

:

:

Product Information

Product Usage Information

(a) Wash membrane-bound HRP (antibody conjugate) three times for 5 minutes in TBS/T.
(b) Prepare 1x SignalFire Plus ECL Reagent by diluting one part 2X Reagent A (#65293) and one part 2X Reagent B (#82201) (e.g., for 10 ml, add 5 ml Reagent A and 5 ml Reagent B). Mix well.
(c) Incubate substrate with membrane for 1 minute, remove excess solution (membrane remains wet), wrap in plastic, and expose to X-ray film.
​​​​​​​*Avoid repeated exposure to skin (see enclosed Material Safety Data Sheet or refer to our website for further information).

Solutions and Reagents

Each SignalFire™ ECL Reagent (A and B) is a 2X concentrate; there is no need to further dilute in water when the two reagents are combined.

Storage

SignalFire ECL Reagent is stable at room temperature. DO NOT store Reagents A and B pre-mixed. Reagents A and B should be combined just prior to exposing membranes.

Product Description

SignalFire ECL Reagent from Cell Signaling Technology (CST) is an enhanced chemiluminescent substrate capable of detecting picogram amounts of protein by western blot analysis. Compared to entry-substrates, SignalFire ECL Reagent boasts a more robust signal and extended duration of signal output. In the presence of hydrogen peroxide, horseradish peroxidase (HRP) converts luminol to an excited intermediate dianion. This dianion emits light on return to its ground state. Light emission is maximal immediately after exposure of the substrate to HRP and continues for 1 hour. Light can be captured on X-ray film, typically by exposure for a few seconds. Maximum sensitivity can be obtained with longer exposure.

Background

Chemiluminescence systems have emerged as the best all-around method for western blot detection. They eliminate the hazards associated with radioactive materials and toxic chromogenic substrates. The speed and sensitivity of these methods are unequalled by traditional alternatives, and because results are generated on film, it is possible to record and store data permanently. Blots detected with chemiluminescent methods are easily stripped for subsequent reprobing with additional antibodies. HRP-conjugated secondary antibodies are utilized in conjunction with specific chemiluminescent substrates to generate the light signal. HRP conjugates have a very high turnover rate, yielding good sensitivity with short reaction times.

Species Reactivity

Species reactivity is determined by testing in at least one approved application (e.g., western blot).

Applications Key

WB: Western Blotting

Cross-Reactivity Key

H: human M: mouse R: rat Hm: hamster Mk: monkey Vir: virus Mi: mink C: chicken Dm: D. melanogaster X: Xenopus Z: zebrafish B: bovine Dg: dog Pg: pig Sc: S. cerevisiae Ce: C. elegans Hr: horse GP: Guinea Pig Rab: rabbit All: all species expected

Trademarks and Patents

Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
SignalFire is a registered trademark of Cell Signaling Technology, Inc.
All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

使用に関する制限

法的な権限を与えられたCSTの担当者が署名した書面によって別途明示的に合意された場合を除き、 CST、その関連会社または代理店が提供する製品には以下の条件が適用されます。お客様が定める条件でここに定められた条件に含まれるものを超えるもの、 または、ここに定められた条件と異なるものは、法的な権限を与えられたCSTの担当者が別途書面にて受諾した場合を除き、拒絶され、 いかなる効力も効果も有しません。

研究専用 (For Research Use Only) またはこれに類似する表示がされた製品は、 いかなる目的についても FDA または外国もしくは国内のその他の規制機関により承認、認可または許可を受けていません。 お客様は製品を診断もしくは治療目的で使用してはならず、また、製品に表示された内容に違反する方法で使用してはなりません。 CST が販売または使用許諾する製品は、エンドユーザーであるお客様に対し、使途を研究および開発のみに限定して提供されるものです。 診断、予防もしくは治療目的で製品を使用することまたは製品を再販売 (単独であるか他の製品等の一部であるかを問いません) もしくはその他の商業的利用の目的で購入することについては、CST から別途許諾を得る必要があります。 お客様は以下の事項を遵守しなければなりません。(a) CST の製品 (単独であるか他の資材と一緒であるかを問いません) を販売、使用許諾、貸与、寄付もしくはその他の態様で第三者に譲渡したり使用させたりしてはなりません。また、商用の製品を製造するために CST の製品を使用してはなりません。(b) 複製、改変、リバースエンジニアリング、逆コンパイル、 分解または他の方法により製品の構造または技術を解明しようとしてはなりません。また、 CST の製品またはサービスと競合する製品またはサービスを開発する目的で CST の製品を使用してはなりません。(c) CST の製品の商標、商号、ロゴ、特許または著作権に関する通知または表示を除去したり改変したりしてはなりません。(d) CST の製品をCST 製品販売条件(CST’s Product Terms of Sale) および該当する書面のみに従って使用しなければなりません。(e) CST の製品に関連してお客様が使用する第三者の製品またはサービスに関する使用許諾条件、 サービス提供条件またはこれに類する合意事項を遵守しなければなりません。

Revision 2
#6883

SignalFire ECL Reagent

Western Blotting Image 1: SignalFire™ ECL Reagent Expand Image
SignalFire ECL Reagent is sensitive enough to detect picogram levels of protein. Western blot analysis of diluted recombinant human Akt-1 protein using Akt (pan) (C67E7) Rabbit mAb #4691.